WIFI Zigbee Radiator Actuator
User Manual
Many thanks for your selection of our products and services, and also for your trust and support to us.
Search for “Smart RM” or “Smart Life” Download the Wifi App with the following icon
https://smartapp.tuya.com/smartroom
- Add your gateway to the App, then add your radiator actuator to your gateway in the App
- After the actuator has completed the self-test, press
about 3s access setting interface, click
or
until
blink and press
, press and hold
until
rapidly blinking, connection begin.
Note: Your smartphone and gateway must be connected to the same wireless router
Product Specifications
Power: 2*2 AA* 1.5V alkaline b | Insulating condition: Normal environment |
Display accuracy::0.5℃ | Running program: Set per 1 week as a cycle |
Probe sensor::NTC(10k)1% | Size(mm):53*89.5 |
Maximum route:4.5mm | Range of temperature display::1~70°C |
The default range of temperature adjustment:5~35°C | Maximum current:90mA |
Working environment temperature::-10~60°C | Thread size: M30*1.5 |
NO: |
Icon |
|
A |
![]() ![]() ![]() ![]() |
|
B |
![]() ![]() ![]() ![]() |
|
C |
![]() ![]() |
|
NO: |
key |
represent |
D |
![]() |
1. short press to set automatic and manual mode. 2. long press 3s to enter setting interface 3. confirm key |
E |
|
represent |
F |
![]() |
1. Increasing key 2. long press it into boost mode |
Install the actuator with the valve and power-on, all of the icons appear, 3s later display program version NO.
Continuous click until “Ad” appear, press
again, actuator begins self-testing, self-testing is finished, working interface appear
Malfunction
error code | description |
E1 | Route is too short: in the adjustment process, the pin was stuck before it reach the destination of 2mm. |
E2 | The temperature sensor is open or damaged |
![]() |
flashing indicates low battery |
Note: After malfunction is solved, click to self-test again
Function description
Mode | Explain |
Holiday mode | press![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Ventilation on and energy saving | Ventilation and energy-saving function is default off, if you want to open this function, please set in advanced options(The default settings will be restored when the battery is replaced ) |
BOOST | Press and hold![]() |
Time setting
Press about 3s access setting interface, click
or
until
blink, press
to confirm and
appear, press
or
to adjust hour value, press
to confirm and appear, press
or
to adjust the minute value, press
to confirm and the number appears, press
or
to adjust week value,
press to confirm.
Programming mode setting
Press about 3s access setting interface, click
or
until
blink, press
enter programming, click
until the mode you want blink (5 represent 5+2 days, 6 represent 6+1 days, 7 represent 7 days ), press
to enter first time period hour setting, press
or
to adjust the value, press
enters minute setting, press
or
to adjust the value, press
enters temperature setting, press or to adjust the value, press to set second time period, thirdly time period ……
After finishing all time periods, press to save and exit. If you exit before finishing all of the settings, don’t operate, after 5s it will automatically save and return to the working interface.
Programmable(default):
period | Default period | Default temperature |
1 | 6:00-8:00 | 20°C |
2 | 8:00-11:30 | 15°C |
3 | 11:30-12:30 | 15°C |
4 | 12:30-17:30 | 15°C |
5 | 17:30-22:00 | 20°C |
6 | 22:00-6:00 | 15°C |
Advanced options
Press about 3s to access setting interface,click
or
until set blink, press
to access advanced options, press
or
to change the value, press to set next item, after finishing all, don’t operate, after 10s it will automatically save and exit.
Symbol | Setting item | Parameter | default |
AI | Measure the temperature correction | -9-+9r | it |
A2 | Window ventilation function |
display• ![]() ![]() ![]() ![]() temperature( temperature limit: 5-25r ), press ![]() |
(.display means close 2.Valve closing time default 15 minute |
A3 | Automatic lock if no operation more than 10 minutes |
01 close 1: open |
0 |
A4 | The minimum limit of the setting temperature | I-16r | 5r |
A5 | The maximum limit of the setting temperature | 16-70t | 35t |
A6 |
Extend BOOST running time. per press ![]() |
I OOs-900s | 300(display 30) |
A7 | Check valve opening | 99 mean valve open 100% 5 mean valve open 5% Each increment is 5% | |
A8 | Temperature hysteresis start setting | 0.5-1.5 | 1 |
A9 | Display mode | 0 vertical display I horizontal display | 0 |
AA | Reset |
Display 88, using ![]() ![]() ![]() to 00, press |
- Application:Apartment, Thermostatic valve actuator
- Design Style:Modern
- Place of Origin:Fujian, China
- Brand Name:Haisen
- Model Number: HY368 ZigBee
- Voltage: 2*AAA* 1.5V alkaline batteries
- Setting Temperature Range: 5~35°C (0-70℃)
- Color:White
- Weekly Programmable Mode: 5+2,6+1,7 Days Programmable
- Accuracy: ±0.5°C
- APP: Tuya / Smart Life
- Certifications: RoHS, CE